OPTIMATION OF RHENIUM-OXO-GLUCONATE SYNTHESIS AS A PRECURSOR FOR SYNTHESIS OF RHENIUM (V)-TETROFOSMIN

Authors

  • Widyastuti Center for Radioisotope dan Radiopharmaceutical Technology (PTRR-BATAN) Kawasan Puspiptek Serpong 15314, Tangerang Selatan
  • A. H. Gunawan Center for Radioisotope dan Radiopharmaceutical Technology (PTRR-BATAN) Kawasan Puspiptek Serpong 15314, Tangerang Selatan
  • Sriyono Center for Radioisotope dan Radiopharmaceutical Technology (PTRR-BATAN) Kawasan Puspiptek Serpong 15314, Tangerang Selatan

DOI:

https://doi.org/10.17146/jsmi.2015.16.4.4217

Keywords:

Re-oxo-gluconate, Rhenium-188, Synthesis, Radiochemical purity, Tetrofosmin

Abstract

Rhenium-188 or Rhenium-186 labeled compounds have been widely used as therapeutic radiopharmaceutical for cancer. Most of rhenium (Re) radiopharmaceuticals involve Re with oxidation state of 5, one of which is Re-dioxo-tetrofosmin. Complexes of Re(V)-ligand can be generated fromRe(V)-oxo-gluconate through ligand exchange process. Optimation of rhenium-oxo-gluconate synthesis was carried out by varying mole ratio of gluconate to perrhenate and reaction time, in which 188Re was added to perrhenate solution as radiotracer. Stability study of Re-oxo-gluconate at room temperature and elevating temperature was carried out bymeasuring its radiochemical puritywithin several hours. Radiochemical purity was analysed using 2 systems of paper chromatography with Whatman-3 paper as solid phase, and acetone and saline as mobile phases, respectively. Highest yield was obtained using mole ratio of 6000, i.e 87.43% (SD=3.01%), and the optimum reaction time was 1 hour. Storage at room temperature and elevating temperature resulted in the decrease of radiochemical purity of 10% (within 3 hrs) and 30% (within 1 hour), respectively. Re-dioxo-tetrofosmin which was used as a model of Re(V)-ligand, was obtained through ligand exchange reaction with the yield of 92.1%. The result showed that Re-oxo-gluconate can be successfully synthesized in high yield but low stability.

Downloads

Download data is not yet available.

References

. A. Vrachimis, S. Hermann, D. Máthé, et al., “Systematic evaluation of 99mTc-tetrofosmin versus 99mTc-sestamibi to study murine myocardial perfusion in small animal SPECT/CT”, EJNMMI Research, 2, 2012, pp. 21-30.

. G.A. Alexiou, X. Xourgia, and E. Vartholomatos, “Comparison of 99mTc-Tetrofosmin and 99mTcSestamibi Uptake in Glioma Cell Lines”, Int. Journ Mol. Imaging., pp.1-5, 2014.

. T. Birbilis, N. Boussios, and L. Papatheodossiou, “ 99mTc-Tetrofosmin in the Diagnostic Work Up of a Brain Tumor”, Maedica Journal of Clinical Medicine, 8(4), pp. 347-350, 2013.

. C. Altini, A.N. Asabella, and D. Rubini, “ 18F-FDG PET/CT usefulness vs Tc99m-Tetrofosmin in the assessment of malignant brain gliomas: Report of two cases”, Iran J. Nucl. Med., 23 (2), pp. 128-133, 2015.

. S. Balogova, M. Cambal,A. Simkova, et al., “From preoperative to intraoperative detection of hyper parathyroid using Tc99m-tetrofosmin”, Bratisl Lek Listy, 112 (12), pp. 695-700, 2011.

. C. Sioka, T. Exarchopoulos, I. Tasiou, et al., “Myocardial perfusion imaging with 99 mTc - tetrofosmin SPECT in breast cancer patients that received postoperative radiotherapy: a casecontrol study”, Rad. Oncology, 6, pp. 151-156, 2011.

. F. Orsini , A. Lorenzoni , P.A. Erba ,et al., “Radiopharmaceuticals for Single-Photon Emission Imaging and for Therapy”, in : Nuclear Oncology: Pathophysiology and Clinical Applications, Springer Science+Business Media, New York, pp. 21-29, 2013.

. P. Kremer, Periodic Table of the Elements. ChemGlobe, www.chemglobe.org/ptoe 2000. Retrived in February, 2014.

. P. Leibnitz, G. Reck, H. Pietzsch, et al., Structures of Technetium and Rhenium Complexes, Forschungszentrum Rossendorf, e.V, Institut für Bioanorganische und Radiopharmazeutische Chemie, Dresden, Germany, 2001, pp. 6-13.

. G.B. Saha, Fundamentals of Nuclear Pharmacy, 6th ed., Springer Science+Business Media, New York, pp.101 125, 2010.

. J.A. Osso, Jr, G. Barrio, C.R.B.R. Dias, et al., “Development of Radiopharmaceuticals Based on 188Re and 90Y for Radionuclide Therapy at IPEN-CNEN/SP”, in: Yttrium-90 and Rhenium-188 Radiopharmaceuticals forRadionuclide Therapy, IAEA Radioisotopes and Radiopharmaceuticals Series no. 5, IAEA, Vienna, 2015, pp. 31-54.

. S. Jürgens, W.A. Herrmann, and F.E. Kühn, “Rhenium and technetium based radiopharmaceuticals:

Development and recentadvances”, J. Organometallic Chem, 751, pp. 83- 89, 2014.

. Philippe Collery, Jean D’angelo, and Georges Morgant, “Rhenium complexes and their pharmaceutical use”, European Patent, EP 2575800 A1, pp. 1-31, 2011.

. A.K. Binion, “Radiopharmaceuticals: the Application of Technetium-99m and Rhenium complexes”, Syracuse University Honors Program Capstone Projects, Paper 752, 2014, pp. 1-32.

. C.A. Kluba and T.L. Mindt, “Click-to-Chelate: Development of Technetium and RheniumTricarbonyl Labeled Radiopharmaceuticals”, Molecules, 18, pp. 3206-3226, 2013.

. L. Jie, W. Xuebin and L. Gongxu, “A study of preparation and biodistribution of a new complex: Re-188-tetrofosmin”, Nuclear Techniques 22, pp. 695-699, 1999.

. Widyastuti, “Synthesis and Radiochemical Analysis of Carrier-added Rhenium-188 Tetrofosmin”, Magister Thesis, Padjadjaran University, pp.1-56, 2014.

. B. Noll, T. Kniess, H.S. Friebe, et al., Isot. Environ. Health Stud. 32, pp. 21-29, 1996.

. B. Noll and H. Spies, “Preparation of 188Re gluconate by reduction of 188Re perrhenate by stannous chloride”, in: Institute of Bioinorganic and Radiopharmaceutical Chemistry, Annual Report 2000, 2001, pp.7-8.

. I.N. Booysen, M. Ismaila, T.I.A. Gerber, et al., “Oxo and Oxofree Rhenium(V) Complexes with N, O-donor Schiff Bases”, S. Afr. J. Chem., 65, pp. 174-177, 2012.

. B.K. Panda, U. Senapati, B. Mondal, et al., “Oxidorhenium(V) and Imidorhenium(V) Complexes of Pyridylpyridazine :Oxygen Atom Transfer, Oxidation and Substitution Involving Oxido, Phosphine Oxide and Phosphine Coordination”,Chem. Sci. Trans., 4(2), pp. 337-346, 2015

. N.S.Al-Hokbany, R. Mhafouz, I.J.AlJammaz, et al., “Newoxorhenium(V) complexwithanimidazol[NN] /hydantoin [SN] mixed ligand system, and radiochemical behavior of its oxotechnetium (V) complex analog”, J. Biophys. Chem., 2(2), pp. 92-101, 2011.

. K.C.Amin, S. Patel,A. Doke, et al., “AnAlternative Method for Determining the Radiochemical Purity of 99mTc Tetrofosmin”, J Nucl Med Technol, 39, pp. 51-54, 2011.

. P. Garnuszek, D. Pawlak, M. Maurin, et al., “Comparison of chromatographic methods for quality control of DMSA complexes with 99mTc and 188Re at (III) and (V) oxidation states”, Nucl Med Rev, 15 (2), pp. 95-100, 2012.

. H. Sadeghpour, M. Alavi, M. Shahedi, et al., “Evaluation of radiochemical purities of some radiopharmaceuticals in Shiraz Namazi teaching hospital”, Trends in Pharmaceutical Sciences, 1(1), pp. 15-19, 2015.

. GamalA.H. Gouda, “Stability Constants of Rhenium (V) Metal Complexes with Selected Medicinal Drugs”, P Y R X . J . R e s . E n v . S t u ., 2, pp. 6-14, 2015.

Downloads

Published

31-07-2015

How to Cite

Widyastuti, A. H. Gunawan, & Sriyono. (2015). OPTIMATION OF RHENIUM-OXO-GLUCONATE SYNTHESIS AS A PRECURSOR FOR SYNTHESIS OF RHENIUM (V)-TETROFOSMIN. Jurnal Sains Materi Indonesia, 16(4), 148–153. https://doi.org/10.17146/jsmi.2015.16.4.4217