PENGARUH IMPLANTASI ION ARGON PADA STRUKTUR MIKRO DAN KEKERASAN BAJA AISI 430 UNTUK BAHAN STRUKTUR REAKTOR

Authors

  • Agus Hadi Ismoyo usat Sains dan Teknologi Bahan Maju (PSTBM) - BATAN Kawasan Puspiptek, Serpong 15314, Tangerang Selatan
  • B. Bandriyana usat Sains dan Teknologi Bahan Maju (PSTBM) - BATAN Kawasan Puspiptek, Serpong 15314, Tangerang Selatan
  • B. Bandriyana usat Sains dan Teknologi Bahan Maju (PSTBM) - BATAN Kawasan Puspiptek, Serpong 15314, Tangerang Selatan
  • Parikin Pusat Sains dan Teknologi Bahan Maju (PSTBM) - BATAN Kawasan Puspiptek, Serpong 15314, Tangerang Selatan

DOI:

https://doi.org/10.17146/jsmi.2016.17.2.4208

Keywords:

Implantasi ion Ar , Struktur mikro, Kekerasan

Abstract

PENGARUH IMPLANTASI ION ARGON PADA STRUKTUR MIKRO DAN KEKERASAN BAJA AISI 430 UNTUK BAHAN STRUKTUR REAKTOR. Rekayasa permukaan dengan teknik implantasi ion argon (Ar+) dapat meningkatkan sifat bahan terutama kekerasannya. Implantasi ion argon ini dilakukan pada baja komersial AISI 430 untuk aplikasi bahan komponen reaktor. Perubahan struktur mikro dan kekerasan setelah implantasi diteliti untuk analisis perubahan sifat mekanik bahan. Proses implantasi ion dilakukan pada energi percepatan sebesar 100 keV dengan arus ion 10mA dan waktu implantasi divariasi 30, 60 dan 90menit. Pengamatan struktur mikro dan fasa dilakukan dengan pengujian mikroskop optik dan uji XRD (X-ray diffraction), sedang pengujian kekerasan dilakukan dengan metode pengukuran Vickers. Hasil uji mikroskop optik menunjukkan terjadi proses difusi ion argon ke permukaan baja komersial AISI 430 dengan kedalaman difusi sekitar 0, 5 mikron untuk waktu implantasi 60 menit dan 2 mikron untuk 90 menit implantasi. Hasil uji XRD untuk sampel sebelum dan sesudah implantasi menunjukkan identifikasi refleksi puncak bidang (110), (200) dan (211) berturutan muncul pada sudut difraksi 2θ= 44,57°; 64,86° dan 82,11°. Implantasi ion tidak menumbuhkan puncak dan fasa baru yang menunjukkan hanya terjadi proses substitusi dan bukan interstisi argon terhadap atombesi atau atom krompada kisi kristal BCC. Hal ini disebabkan karena jari-jari atomargon 0,987 Å hampir sama dengan jari-jari kovalen besi yaitu 1,17 Å seperti ini ditunjukkan pada pergeseran sudut difraksi. Perubahan kekerasan terjadi pada proses implantasi sesuai dengan dosis ionArgonmelalui penambahan waktu implantasi.Nilai kekerasan bajameningkat setelah diimplantasi ion argon, semakin lama proses implantasi semakin tinggi kekerasannya.Mula-mula saat baja komersialAISI 430 diimplantasi dengan ion argon selama 30 menit kekerasannya adalah 190,78 HV, kemudian setelah baja komersial AISI 430 diimplantasi dengan ion argon selama 60 menit kekerasannya menjadi 222,53 HV dan setelah baja komersial AISI 430 diimplantasi dengan ion argon selama 90 menit kekerasannya menjadi 241,46 HV.

Downloads

Download data is not yet available.

References

. R Couturier, C. Escaravage. “High Temperature

Alloys For The HTGR Gas Turbine: Required

Properties and Development Needs”. CEREM,

CEA-Grenoble, 2010, pp. 163-166.

. D. Buckthorpe, R. Couturier, B. v.d. Schaaf, et.al.,

“Material for the High TemperatureAlloys For The

HTGR Gas Turbine: Required Properties and

Development Needs”. in Transaction SMiRT16,

Washington D.C, paper #1943 (2001), pp. 1-8.

. William D. Callister, Jr. and David G. Rethwisch.

Materials Science and Engineering, SI Version. John

Wiley & Sons, Inc., 2011, pp. 319-335

. W. F. Lee, C.Y. Wu, C.T. Lin, et.al., “The effect of

nitrogen addition to Ar/CH4

gas mixture on

microstructural characterization of nanocrystalline

diamond”. Journal of Polymer Engineering, 34-3,

pp. 253-258, 2014.

. A. E. Amrani, R. S. Kaddour, M. Maoudj, et.al.,

“Investigation of rapid thermal oxide/ silicon nitride

passivation stack of n+

emitter”. Current Applied

Physics, 15-12, pp. 1563-1567, 2015.

. C.F. Wolle, M.A. Vasconsellos, R.Hinrichs, A.N.

Becker, F.B. Barletta and J Endod., “The effect of

argon and nitrogen ion implantation on nickeltitanium rotary instruments”, 35-11 (2009) 1558-62.

. F. Djurabekova, K. Nordlund, J. Räisänen and T.

Sajavaara. “Transformation of YSZ under high

fluence argon ion implantation”. in Proc. 17th

International Conference on Radiation Effects in

Insulators (REI), 2014, Vol. 326, pp. 283-288.

. F.L. Deng, S.W. Zhu, L.J. Wu , B.J. Cheng.“Effects

of low-energy argon ion implantation on the

dynamic organization of the actin cytoskeleton

during maize pollen germination”. Genet Mol Res.,

-2, pp.785-796, 2010.

. F.Z. Fang, Y.H. Chen, X.D. Zhang, X.T. Hu,, G.X.

Zhang. “Nanometric cutting of single crystal

silicon surfaces modified by ion implantation”.

CIRP Annals Manufacturing Technology, 60-1,

pp. 527-530, 2011.

. Y.H. Chen, Z.W Xu, F.Z. Fang, Y.H. Chen, et.al.,

“Surface modification for brittle monocrystalline

materials by MeV ions”. Nuclear Instruments and

Methods in Physics Research Section B: Beam

Interactions with Materials and Atoms, 272,

pp. 433-436, 2012.

. I. Wahyono, R. Salam, A. Dimyati, Parikin.

“Karakterisasi strukturmikro menggunakan SEM

dan XRD pada ketahanan korosi baja komersial

SS430 dan baja non komersial F1”. dalam Pros. Sem.

Nas. XI SDM TN - Yogyakarta, 2015, hal. 112-117.

. C.E. Dubé, B.T.D Buzby, R. Tavares, et.al., “High

efficiency selective emitter cells using patterned

ion implantation”. in Proc. of The 1st International

Confr. on Crystalline Silicon Photovoltaics, 2011.

. M. Braic, M. Balaceanu, A. Vladescu, et.al.,

“Deposition and characterization of multi-principalelement (CuSiTiYZr)C coatings”. Applied Surface

Science, 284, pp. 671-678, 2013.

. V. Braic, M. Balaceanu, M. Braic , et.al.,

“Characterization of multi-principal-element

(TiZrNbHfTa)N and (TiZrNbHfTa)C coatings for

biomedical applications”. Journal of the

Mechanical Behavior of Biomedical Materials,

, pp.197-205, 2012.

. C. Jagadish, S. J. Pearton. “Ion Implantation into

ZnO in Technology & Engineering” . Charon

Tech., Chennai India, pp. 285-313, 2011

Downloads

Published

31-01-2016

How to Cite

Agus Hadi Ismoyo, B. Bandriyana, B. Bandriyana, & Parikin. (2016). PENGARUH IMPLANTASI ION ARGON PADA STRUKTUR MIKRO DAN KEKERASAN BAJA AISI 430 UNTUK BAHAN STRUKTUR REAKTOR. Jurnal Sains Materi Indonesia, 17(2), 90–94. https://doi.org/10.17146/jsmi.2016.17.2.4208