KAJIAN KINERJA POLYMER ELECTROLYTE MEMBRANE FUEL CELL OPEN CATHODE TERHADAP VARIASI TEGANGAN KIPAS KATODA DAN VARIASI LAJU ALIR HIDROGEN

Authors

  • Yuyun Irmawati Pusat Penelitian Fisika (P2F) - LIPI Kawasan Puspiptek, Serpong 15314, Tangerang Selatan.
  • Indriyati Pusat Penelitian Fisika (P2F) - LIPI Kawasan Puspiptek, Serpong 15314, Tangerang Selatan.
  • Holia Onggo Pusat Penelitian Fisika (P2F) - LIPI Kawasan Puspiptek, Serpong 15314, Tangerang Selatan.
  • Rike Yudianti Pusat Penelitian Fisika (P2F) - LIPI Kawasan Puspiptek, Serpong 15314, Tangerang Selatan.

DOI:

https://doi.org/10.17146/jsmi.2012.13.3.4675

Keywords:

PEMFC, Open Cathode, Fitting Kurva Polarisasi, Polarisation Curve Fitting

Abstract

KAJIAN KINERJA POLYMER ELECTROLYTE MEMBRANE FUEL CELL OPEN CATHODE TERHADAP VARIASI TEGANGAN KIPAS KATODA DAN VARIASI LAJU ALIR HIDROGEN. Kajian untuk pengaruh variasi tegangan kipas dan laju alir gas hidrogen terhadap hasil rapat daya serta fitting kurva potensial untuk mendapatkan parameter overpotensial pada Polymer Electrolyte Membrane Fuel Cell (PEMFC) dengan sistem open cathode telah dilakukan. Pada stack PEMFC yang terdiri atas dua sel dengan aktif area 30 cm2, dipasang tegangan kipas dengan variasi 3 Volt hingga 12 Volt yang berasal dari tegangan listrik eksternal. Dari rapat daya yang diperoleh, variasi tegangan kipas, yang berfungsi sebagai pendingin stack dan mampu meningkatkan produksi rapat daya sebesar 47 % hingga 67 % dibandingkan bila tidak menggunakan kipas. Nilai rapat daya maksimal (73,26 mW/cm2) diperoleh pada tegangan kipas 3 Volt. Untuk variasi laju alir hidrogen yang rendah sebesar 20 mL/menit hingga 40 mL/menit, diperoleh adanya dead point disebabkan ketidakseimbangan stoikiometri hidrogen dengan oksigen sehingga potensial sel turun tajam menuju nol. Pada laju alir hidrogen 50 mL/menit menghasilkan nilai rapat daya optimum sebesar 79 mW/cm. Berdasarkan hasil fitting kurva polarisasi dengan persamaan empiris, penambahan laju alir hidrogen menyebabkan meningkatnya overpotensial aktivasi dan menurunnya overpotensial difusi yang disebabkan oleh faktor hidrogen crossover dan dehidrasi membran, sedangkan untuk overpotensial ohmik terlihat relatif konstan.

ABSTRACT

STUDYING ON INFLUENCE OF VARIATION FOR VOLTAGES AND HYDROGEN RATES TO POWER DENSITY PRODUCTION OF POLYMER ELECTROLYTE MEMBRANE FUEL CELL. The studying on influence of variation fan voltages and hydrogen flow rates to power density production of polymer electrolyte membrane fuel cell (PEMFC) had been done. There was also a polarisation curve fitting method to investigate dependence of over potential losses with variation hydrogen flow rates (20-100 mL/minute). Double cells of open cathode PEMFCs stack with active area of 30 cm2 was applied with different fan voltages (3-12 Volt) which were got from external electric circuit. As a result, there was an increase of power density in the voltage variation by 47-67% (compared with power density without fan) which rose from 45.16 mW/cm2 to about 70 mW/cm2. The highest power was achieved from 3 volt of fan voltage (73.26 mW/cm2). From the variation of hydrogen flow rates, dead point, which was caused by unbalance stoikiometri between hydrogen and oxygen, was introduced at low flow rate (20-40 mL/minute) and the optimum power (79 mW/cm2) was the result of 50 mL/minute of hydrogen flow rate. Based on polarisation curve fitting, increasing hydrogen flow rate caused increased in activation over potential activation but decreased in diffusion over potential which were results of hydrogen crossover and membrane dehydration. Meanwhile, the ohmic over potential remained constant for all hydrogen flow rate.

Downloads

Download data is not yet available.

References

CHU, D. and JIANG, R., Journal of Power Sources, 83 (1999) 128-133

ROSA, D. T. S., PINTOA, D. G., SILVAA, V.S., SILVAB, R. A., RANGELB, C. M., International Journal of Hydrogen Energy, 32 (2007) 4350-4357

SANTARELLI, M. G. and M. F. TORCHIO, Energy Conversion and Management, 48 (2007) 40-51

MATTI, N., T. MENNOLA, M. MIKKOLA, T. HOTTINEN, P. LUND, Journal of Power Sources, 160 (2002) 304-312

SASMITO, A. P., E. BIRGERSSON, K. W. LUM, A. S. MUJUMDAR, Renewable Energy, 37 (2012) 325-332

FRASER, S. D. and HACKER, V., Journal of Applied Electrochemistry, 38 (2008) 451-456

HAJI, S., Renewable Energy, 36 (2011) 451-458

YU, D. and YUVARAJAN, S., Journal of Power Sources, 142 (2005) 238-242

KIM, J. LEE, S. M., SRINIVASAN, S., CHAMBERLIN, C. E., Journal of The Electrochemical Society, 142 (8) (1995)

YANG, T. H., G. PARK, P. PUGAZHENDHI, S. Y. LEE, C. S. KIM, Korean J. Chem. Eng., 9 (3) (2002) 417-420

RIKUKAWA, M. and SANUI K., Progress in Polimer Science, 25 (10) (2000) 1463-1502

FRANO, BARBIER., PEM Fuel Cells: Theory and Practice. Elsiever, (2005)