OPTIMASI PENDINGINAN EKSTERNAL PADA MODEL SUNGKUP PWR-1000 MENGGUNAKAN METODE ESTIMASI ANALITIK
Keywords:
external cooling, PWR containment, analytical estimation, AP1000Abstract
Reactor containment is the last barrier in avoiding the release of radioactive substances into the environment in the event of a reactor accident. Therefore, its integrity must always be maintained, among others, performed in a manner to prevent the exceeding of pressure and temperature design limit that could occur in an accident, through adequate containment cooling. In generation III + reactors which passive cooling concepts are applied such as the AP1000, the containment is externally cooled by natural convection in the air gap and a splash of cooling water in the outer surface. External cooling characteristics will be investigated experimentally through PWR1000 containment models of 1/40 scale. The purpose of this research is to determine the optimal flow of cooling required in the model before confirming experimentally performed. The method used is to perform analytical modeling and programming based on Matlab which is able to estimate the values of external cooling parameters such as flow rate, temperature and heat power evacuated. Implementation of the program on the AP1000 containment is also performed to be compared with the design data. The results shows the conformity with the AP1000 containment design data with optimal flow of 9.5 liters/sec that is able to evacuate the heat of 21.6 MW. While for the containment model, the optimal flow obtained at 22 cc / sec which is capable of evacuating the heat by 37 KW. This study concluded that the characteristics of the external cooling of PWR containment could be estimated and in conjunction, the optimal cooling flow required can be determined.
References
Hashim Muhammad, Yoshikawa Hidekazu, Matsuoka Takeshi, Yang Ming.Common cause failure analysis of PWR containment spray system by GO-FLOW methodology. Nuclear Engineering and Design. 2013; 262: 350-357.
https://doi.org/10.1016/j.nucengdes.2013.04.028
YE Cheng. A study of long-term completely passive cooling of the AP1000 reactor. Proceedings of ICAPP 2013, Jeju Island, Korea; 2013.p. 14-18.
Wang Yan. Preliminary study for the passive containment cooling system analysis of the advanced PWR. Asian Nuclear Prospects 2012, Energy Procedia 39; 2013.p. 240 - 247.
https://doi.org/10.1016/j.egypro.2013.07.210
Andi Sofrany Ekariansyah, Surip Widodo, Susyadi, D.T. Sony Tjahyani, Hendro Tjahjono. Verifikasi kecelakaan hilangnya aliran air umpan pada reaktor daya PWR maju. Jurnal Teknologi Reaktor Nuklir. 2012; 14(2): 76-90.
Hendro Tjahjono, Susyadi. Giarno, Adhi Rahardian. Pemodelan sungkup PWR untuk eksperimen dinamika pembebanan dan kondensasi. Laporan Teknis PTRKN-BATAN; 2010.
Westinghouse Inc. Design of Structures, Components, Equipment and Systems", AP1000 Design Control Document, Revision 18; 2011.
A.D. Pasek, E. Umar, A. Suwono and R.E. Manalu. Experimental study on the heat transfer characteristics of a nuclear reactor containment wall cooled by gravitationally falling water. Presented at International Conference on Advances in Nuclear Science and Engineering 2011, Bali, Indonesia; 2011.
https://doi.org/10.1063/1.4725461
A. D. Pasek, E. Umar, A. Suwono and D. Anggraini. Numerical analysis of natural convection air cooling on containment of AP-1000 reactor model. Proceedings of 5th International Conference on Cooling and Heating Technologies, Bandung; 2010.
A.D. Pasek, D. Hidayanti, N.P. Tandian, E. Umar and A. Suwono. Numerical study on the characteristics of the AP1000 passive containment cooling system by the laminar subcooled falling water film. Proceedings of International Conference on Fluid and Thermal Energy Conversion, Tongyeong, Korea; 2009.
Incropera & De Witt. Fundamental of heat and mass transfer. John Wiley & Son, 4th edition, 1996.
J.P. Holman, "Heat Transfer, SI Metric Edition", McGraw-Hill Book Company; 1986.
Caruso G. - Naviglio A. The influence of noncondensable gases on condensation inside tubes: An experimental analysis. Technical Repport of Project Contract No. FI4S CT-96-0042 supported by the MURST and EU; 1996.
B.Manikandaprabu, S.Mohankumar & R.Kathiravan. "Pool Boiling Of Water Over A Stainless Steel Flat Plate Heater", International Journal of Instrumentation, Control and Automation (IJICA) ISSN: 2231-1890, Vol-1 Iss-3,4, 2012.
https://doi.org/10.47893/IJICA.2012.1058
Chokri Debbissi Hfaiedh, Abdelaziz Nasr*, Sassi Ben Nasrallah. Evaporation of a binary OLTXLG ¿OP ÀRZLQJ GRZQ WKH ZDOO RI WZR vertical plates. International Journal of Thermal Sciences. 2013; 72: 34-46.
https://doi.org/10.1016/j.ijthermalsci.2013.05.005
Satish G. Kandlikar, Wai Keat Kuan, Abhijit Mukherjee. Experimental study of heat transfer in an evaporating meniscus on a moving heated surface. Transactions of the ASME, Vol. 127; 2005.
https://doi.org/10.1115/1.1857948
D.G.Kroger dan G.R.Branfield. Evaporation from a water surface. R&D Journal of South African Institution of Mechanical Engineering . 2007; 23.
Massimo Corcione. Heat transfer correlations for free convection from upward-facing horizontal rectangular surfaces. Wseas Transactions On Heat And Mass Transfer, Manuscript received Jun. 23, 2007; revised; 2007.
Nanang Triagung Edi Hermawan1, Ari Darmawan Pasek, dan Efrizon Umar. Karakteristik perpindahan panas pada pendinginan model sungkup reaktor AP1000 dengan udara yang bersirkulasi alamiah. LIPI Press 2011 Teknologi Indonesia; 2011.