THERMAL NEUTRON FLUX MAPPING ON A TARGET CAPSULE AT RABBIT FACILITY OF RSG-GAS REACTOR FOR USE IN k0-INAA

Authors

  • Sutisna Center of Technology for Nuclear Industrial Materials National Nuclear Energy Agency (BATAN)

Keywords:

thermal neutron, flux, capsule, NAA

Abstract

Instrumental neutron activation analysis based on the k0 method (k0-INAA) requires the availability of the accurate reactor parameter data, in particular a thermal neutron flux that interact with a targets inside the target capsule. This research aims to determine and map the thermal neutron flux inside the capsule and irradiation channels used for the elemental quantification using the k0-AANI. Mapping of the thermal neutron flux (фth) on two type of irradiation capsule have been done for RS01 and RS02 facilities of RSG-GAS reactor. Thermal neutron flux determined using Al-0,1%Au alloy through 197Au(n,g) 198Au nuclear reaction, while the flux mapping done using statistics R. Thermal neutron flux are calculated using k0-IAEA software provided by IAEA. The results showed the average thermal neutron flux is (5.6±0.3)×10+13 n.cm-2.s-1; (5.6±0.4)×10+13 n.cm-2.s-1; (5.2±0.4)×10+13 n.cm-2.s-1 and (5.3±0.4)×10+13 n.cm-2.s-1 for Polyethylene capsule of 1st , 2nd, 3rd and 4th layer respectively. In the case of Aluminum capsule, the thermal neutron flux was lower compared to that on Polyethylene capsule. There were (3.0±0.2)×10+13 n.cm-2.s-1; (2.8±0.1)×10+13 n.cm-2.s-1; (3.2±0.3)×10+13 n.cm-2.s-1 for 1st, 2nd and 3rd layers respectively. For each layer in the capsule, the thermal neutron flux is not uniform and it was no degradation flux in the axial direction, both for polyethylene and aluminum capsules. Contour map of eight layer on polyethylene capsule and six layers on aluminum capsule for RS01 and RS02 irradiation channels had a similar pattern with a small diversity for all type of the irradiation capsule.

 

 

References

IAEA. Report of the IAEA CMs on preparation of guidelines on implementation of routine automation in neutron activation analysis laboratories, Vienna, Austria; December 2009.

IAEA. Draft report based on result of the IAEA questionnaire on status of implementation of routine automation in advanced neutron activation analysis laboratories, Vienna, Austria; June 2011.

IAEA. Draft meeting report of the 1st research coordination meeting related to the IAEA coordinated research project 1888/F1.20.25 on development of an integrated approach to routine automation of NAA, Technical University of Delft, Delft, The Netherlands; 2012 August 27-31.

Rossbach M, Menno B, Bacchi MA, Xilie Lin. The k0-IAEA program, J Radioanal Nucl Chem.2007; 274(3): 657-62.

https://doi.org/10.1007/s10967-007-7104-4

Frans de Corte.The k0-Standardization Method, Rijksuniversiteit Gent;1987.

Amir Hamzah. Analisis parameter f dan a serta faktor k0 di fasilitas iradiasi reaktor RSG. GA. Siwabessy, Jurnal Teknologi Reaktor Nuklir.2003;(5)2: 49-58 .

Syaiful Bakhri, Amir Hamzah. Pengembangan metode koinsiden untuk penentuan fluks neutron termal RSG-GAS, Jurnal Teknologi Reaktor Nuklir.2004:6(1);12-21.

Jaka Iman, Saleh Hartaman, Arsunadi, Royadi. Evaluasi fluks neutron termal di fasilitas iradiasi sistem rabbit RSG. GA. Siwabessy. Prosiding Seminar Penelitian dan Pengelolaan Perangkat Nuklir;2009 Oktober, PTAPB, Yogyakarta;1992.p.275-81.

Sutisna, Saeful Yusuf, Sumardjo. Aplikasi metode k0-AANI di reaktor GA. Siwabessy, Prosiding Seminar Nasional AAN 2008; 2008 Oktober 22. Sabuga ITB. Bandung;2008.p.292-305.

Sutisna, Saeful Yusuf, Rukihati, Th Rina Mulyaningsih. Analisis polutan di pesisir utara Banten menggunakan metode k0-AANI di reaktor GA. Siwabessy. Prosiding Seminar Nasional AAN 2008;2008 Oktober 22. Sabuga ITB, Bandung; 2008.p.229-36.

Sogbadji RDM, Nyarko BJB, Akaho EHK, Abrefah RG. Determination of neutron fluxes and spectrum shaping factors in irradiation sites of Ghana's miniatur neutron source reactor (MNSR) by activation method after compensation of loss of excess reactivity, Word Journal of Nuclear Science and Technology. 2011;1:50-6.

https://doi.org/10.4236/wjnst.2011.12009

Sadiq U, Jonah SA, Nasiru R, Zakari YI. Neutron spectrum parameters in two irradiation channels of the Nigeria research reactor-1 (NIRR-1) for use in k0-NAA. Bayero Journal of Pure and Applied Science. 2010; 3(1):220-23.

https://doi.org/10.4314/bajopas.v3i1.58797

Ilca MMAM, Jose AGM, Cibele BZ. Software for determination of the thermal neutron flux on nuclear reactor. 2009 International Nuclear Atlantic Conference; 2009 September 27- October 2. Rio de Janeiro, RJ, Brazil;2009.

Forina AF, Strijckmans K, Vermaerck P, Verheyen L, Sneyers L. The impact of polyethylene vials on reactor channels characterization in k0-NAA. J Radioanal Nucl Chem. 2010;286:569-75.

https://doi.org/10.1007/s10967-010-0783-2

Downloads

Published

2015-03-29

How to Cite

Sutisna. (2015). THERMAL NEUTRON FLUX MAPPING ON A TARGET CAPSULE AT RABBIT FACILITY OF RSG-GAS REACTOR FOR USE IN k0-INAA. Jurnal Teknologi Reaktor Nuklir Tri Dasa Mega, 15(1), 27–35. Retrieved from https://ejournal.brin.go.id/tridam/article/view/2413