A CONCEPTUAL DESIGN OF NEUTRON COLLIMATOR IN THE THERMAL COLUMN OF KARTINI RESEARCH REACTOR FOR IN VITRO AND IN VIVO TEST OF BORON NEUTRON CAPTURE THERAPY

Authors

  • Nina Fauziah Department of Physics Engineering - Engineering of Faculty UGM
  • Andang Widiharto Department of Physics Engineering - Engineering of Faculty UGM
  • Yohannes Sardjono Center of Accelerator and Material Process Technology - BATAN

Keywords:

design, collimator, epithermal neutron beam, BNCT, MCNP, criteria

Abstract

Studies were carried out to design a collimator which results in epithermal neutron beam for IN VITRO and IN VIVO of Boron Neutron Capture Therapy (BNCT) at the Kartini research reactor by means of Monte Carlo N-Particle (MCNP) codes. Reactor within 100 kW of thermal power was used as the neutron source. The design criteria were based on recommendation from the International Atomic Energy Agency (IAEA). All materials used were varied in size, according to the value of mean free path for each material. MCNP simulations indicated that by using 5 cm thick of Ni as collimator wall, 60 cm thick of Al as moderator, 15 cm thick of 60Ni as filter, 2 cm thick of Bi as γ-ray shielding, 3 cm thick of 6Li2CO3-polyethylene as beam delimiter, with 1 to 5 cm varied aperture size, epithermal neutron beam with maximum flux of 7.65 x 108 n.cm-2.s-1 could be produced. The beam has minimum fast neutron and γ-ray components of, respectively, 1.76 x 10-13 Gy.cm2.n-1 and 1.32 x 10-13 Gy.cm2.n-1, minimum thermal neutron per epithermal neutron ratio of 0.008, and maximum directionality of 0.73. It did not fully pass the IAEA’s criteria, since the epithermal neutron flux was below the recommended value, 1.0 x 109 n.cm-2.s-1. Nonetheless, it was still usable with epithermal neutron flux exceeding 5.0 x 108 n.cm-2.s-1. When it was assumed that the graphite inside the thermal column was not discharged but only the part which was going to be replaced by the collimator, the performance of the collimator became better within the positive effect from the surrounding graphite that the beam resulted passed all criteria with epithermal neutron flux up to 1.68 x 109 n.cm-2.s-1.

 

References

IAEA Nuclear Instalation Safety - NUSAFE, Reactor Physics, Nuclear Safety IAEA; Module 1 - Module 15; 2009.

Herman Chamber, Thomas E. Johnson. Introduction to Health Physics: New York, 4th Edition: McGraw-Hill; 2009.

Wolfgang A. G. Sauerwein and Ray L. Moss. Requirements for Boron Neutron Capture Therapy (BNCT) at a Nuclear Research Reactor. A technical document, EUR 23830 EN, European Commission Joint Research Centre, Luxembourg; 2012:1 - 5.

https://doi.org/10.1007/978-3-642-31334-9_32

D. Rorer, A. Wambersie, G. Whitmore, R. Zamenhof, V. Levin, P. Andreo, and B. Dodd. Current Status of Neutron Capture Therapy. A technical document, IAEA-TECDOC-1223, International Atomic Energy Agency, Vienna; 2001.

Marko Maučec. Conceptual Design of Epithermal Neutron Beam for BNCT in Thermal Column of TRIGA Reactor. Nuclear Energy in Central Europe, Ljubljana, 1998.

James Michaelson, Sameer Satija, Richard Moore, Griffin Weber, Elkan Halpern, Andrew Garland, Daniel B. Kopans, and Kevin Hughes. Estimates of the sizes at which breast cancers become detectable on mammographic and clinical grounds. Journal of Women's Imaging. 2003; 5: 3-10.

https://doi.org/10.1097/00130747-200302000-00002

Thomas E. Booth, John T. Goorley, Avneet Sood, Forrest B. Brown, H. Grady Hughes, Jeremy E. Sweezy, Jeffrey S. Bull, Russell D. Mosteller, Richard F. Barrett, Lawrence J. Cox, Richard E. Prael, Susan E. Post, R. Arthur Forster, Elizabeth C. Selcow, and Teresa L. Roberts. MCNP-A General Monte Carlo N-Particle Transport Code, Version 5, Volume I: Overview and Theory. A technical document, LA-UR-03-1987, Los Alamos National Laboratory, California; 2003.

Sofia Mubarika. Analisis dan Penentuan Distribusi Fluks Neutron Termal Arah Axial dan Radial Teras Reaktor Kartini dengan Detektor Swadaya. An undergraduate thesis, Faculty of Mathematics and Science, Universitas Diponegoro, Semarang, 2006.

Robert W. Young and George D. Kerr. Reassessment of the Atomic Bomb Radiation Dosimetry for Hiroshima and Nagasaki: Dosimetry System 2002. A research report, Radiation Effects Research Foundation, Hiroshima; 2005.

Downloads

Published

2015-03-29

How to Cite

Fauziah, N., Widiharto, A., & Sardjono, Y. (2015). A CONCEPTUAL DESIGN OF NEUTRON COLLIMATOR IN THE THERMAL COLUMN OF KARTINI RESEARCH REACTOR FOR IN VITRO AND IN VIVO TEST OF BORON NEUTRON CAPTURE THERAPY. Jurnal Teknologi Reaktor Nuklir Tri Dasa Mega, 15(2), 112–119. Retrieved from https://ejournal.brin.go.id/tridam/article/view/2420