METODE KALIBRASI ONLINE UNTUK PEMANTAUAN KONDISI PERANGKAT INSTRUMENTASI REAKTOR NUKLIR BERBASIS ELECTRICAL SIGNATURE ANALYSIS

Authors

  • Syaiful Bakhri Pusat Teknologi dan Keselamatan Reaktor Nuklir, BATAN

Keywords:

condition monitoring, online calibration, electrical signature analysis

Abstract

Electrical signature analysis currently becomes an alternative in condition monitoring in nuclear power plants not only for stationary components such as sensors, measurement and instrumentation channels, and other components but also for dynamic componentssuch as electric motors, pumps, generator or actuators. In order to guarantee the accuracy, the calibration of monitoring systemis anecessary which practically is performed offline, under limited schedules and certain tight procedures. This research aims to introduce online calibration technique for electrical signature condition monitoring in order that the accuracy can be maintained continuously which in turn increases the reactor safety as a whole. The research was performed step by stepin detail from the conventional technique, online calibration using baseline information and online calibration using differential gain adjustment. Online calibration based on differential gain adjustment provides better results than other techniques even tough under extreme gain insertion as well as external disturbances such as supply voltages.

 

 

References

Hashemian HM. Aging management of instrumentation control sensors in nuclear power plants. Nuclear Engineering and Design. 2010;240(11):3781-90.

https://doi.org/10.1016/j.nucengdes.2010.08.014

Agency IAE. On-Line Monitoring for Improving Performance of Nuclear Power Plants Part 2 : Process and Component Condition Monitoring and Diagnostics: International Atomic Energy Agency; 2008.

Agency IAE. On-Line Monitoring for Improving Performance of Nuclear Power Plants Part 1 : Instrument Channel Monitoring International Atomic Energy Agency; 2008.

Benbouzid MEH. Review of induction motors signature analysis as a medium for faults detection. IEEE Transactions on Industrial Electronics. 2000;47(5):984-93.

https://doi.org/10.1109/41.873206

Harke MC, Lorenz RD. The Spatial Effect and Compensation ofCurrent Sensor Differential Gains for Three-Phase Three-Wire Systems. IEEE Transactions on Industry Applications. 2008;44(4):1181-9.

https://doi.org/10.1109/TIA.2008.926208

Younghoon C, LaBella T, Jih-Sheng L. A Three-Phase Current Reconstruction Strategy With Online Current Offset Compensation Using a Single Current Sensor. IEEE Transactions on Industrial Electronics. 2012;59(7): 2924-33.

https://doi.org/10.1109/TIE.2011.2171177

Won-Sang I, Seon-Hwan H, Jang-Mok K, Jeaho C, editors. Analysis and compensation of current measurement errors in a doubly fed induction generator. Energy Conversion Congress and Exposition, 2009 IEEE ECCE 2009; 2009.

https://doi.org/10.1109/ECCE.2009.5316170

Han-Su J, Seon-Hwan H, Jang-Mok K, Cheul UK, Cheol C. Diminution of Current Measurement Error for Vector-Controlled AC Motor Drives. IEEE Transactions on Industry Applications. 2006;42(5):1249-56.

https://doi.org/10.1109/TIA.2006.880904

Harke MC, Lorenz RD, editors. The spatial effect and compensation of current sensor gain deviation for three-phase three-wire systems. Applied Power Electronics Conference, APEC 2007 - Twenty Second Annual IEEE; 2007.

https://doi.org/10.1109/APEX.2007.357550

Coble J, Hashemian H, Meyer R, Shumaker B, Ramuhalli P, Cummins D, et al. A review of sensor calibration monitoring for calibration interval extension in nuclear power plants 2012: Available from: http://www.ntis.gov/search/product.aspx?ABBR= DE20131061413.

https://doi.org/10.2172/1061413

Downloads

Published

2015-03-29

How to Cite

Bakhri, S. (2015). METODE KALIBRASI ONLINE UNTUK PEMANTAUAN KONDISI PERANGKAT INSTRUMENTASI REAKTOR NUKLIR BERBASIS ELECTRICAL SIGNATURE ANALYSIS. Jurnal Teknologi Reaktor Nuklir Tri Dasa Mega, 15(3), 124–136. Retrieved from https://ejournal.brin.go.id/tridam/article/view/2421